Connect with us

Concrete

Concrete repair and corrosion control

Published

on

Shares

Corrosion of concrete happens due to various factors but it is necessary to repair the damage caused by such corrosion. In Part-1 of the two-part series, Upen Patel, Business Director, BASF India, dwells at length on the causes of deterioration and the remedy thereofOnce concrete repairs and strengthening was considered as an activity of rejuvenating the old structures and making them capable of loadings and environmental stresses in the future life. Today we are constructing more advanced and ever more-demanding structures with complex detailing and concrete repairs and strengthening starts during the construction stage itself. The complex and fast pace construction methods with reduced emphasis on adequate quality assurance results in to construction errors and creates needs for repairs and strengthening during construction. With the complex performance demands of the new structures and ever longer life expectancies makes concrete repairs, strengthening and protection procedures more and more demanding. This article is an attempt to present the fundamentals of concrete repairs and strengthening in a step-by-step process and focuses on the advantages and disadvantages of current practices and provides an insight in the futuristic but more simple to adopt techniques.Basic DefinitionsRepairs: To replace or correct deteriorated, damaged or faulty materials, components or elements of a concrete structure.Strengthening: The process of restoring the capacity of weakened components or elements to their original design capacity or increasing the strength of components or elements of a concrete structure.Protection: Making the structure capable to resist the likely deterioration due to the surrounding/ environment.Why concrete needs repairs?There are many factors which lead to the need of repairs such as:??Corrosion of reinforcement due to carbonation, chlorides??Sulphates??Alkali silica reaction??Environmental pollution??Deicing salts??Acid rains??Marine environment??Oils??Freeze thaw cycles??Abrasion or erosion from wind or water borne agents??Plants or microorganisms??Overloading??Physical settlement??Impact??Earthquake??Fire??Chemical attack by aggressive chemicals, sewerage or even soft waterAlso the deterioration gets aggravated due to errors/mistakes/poor workmanship during construction such as:??Higher w/c ratio??Honeycombs and compaction voids??Bleeding and segregation??Plastic shrinkages and hardening stage shrinkage cracks??Inadequate or no curing??In sufficient concrete cover??Cast-in chlorides from contaminated water/aggregates??Inadequate or excessive vibration during the concerting??Shutterwork or reinforcement movement during placement of concreteGenerally concrete structure requires repairs in the two events- New construction and during the service life. Repairs in the new construction require different approach then the repairs during service life and we shall deal one by one to better understand. The repairs during service life have more steps and we shall deal with it first. The repairs during service life arise due to certain deterioration taken place and understanding of the same is very vital in the design of the repair solution.Why concrete deteriorates?The reinforced concrete was designed with a basic understanding that its a marriage of two carrying spouses – concrete and steel. Concrete protects steel from getting corroded and steel protects concrete from getting cracked due to bending. The marriage was designed to last forever but the environment facilitates entry of many agents who leads the marriage to divorce…Major agents and their activities are described as under:-Carbonation: The high pH of concrete passivates steel reinforcement from getting corroded. The carbon dioxide / sulphur dioxide present in the atmosphere gets dissolved in the water and forms weak carbonic /sulphuric acid and enters the concrete reducing the pH, resulting in the loss of passivation layer around reinforcement. The reinforcement states getting corroded resulting in to the rust. The rust formed has 4- times the original volume of the metal creating bursting pressure in the concrete mass. The build up of the pressure eventually cracks the concrete and makes the access for ingress of corrosive water and other water dissolved agents easily. The quicker access aggravates the corrosion and structure starts deteriorating rapidly. Spalling of the concrete cover and formation of brown colored rust is a visual indication of the carbonation attack. The carbonation attack can be checked by phenolphthalein liquid. The reaction is at its best at 50-75 % relative humidity.Chloride attack: The main source of chlorides is the contaminated water or aggregates during construction and marine environment – direct contact with sea water or through wind borne chlorides in the splash zone. Chlorides ions are the passivating ferrous oxide layer on the steel reinforcement. Once reinforcement loses its passivation layer, it is highly susceptible to electro-chemical corrosion further induced by chlorides ions. The water dissolved chlorides ions form electro-chemical corrosion cell and establishes anodic and cathodic sites on the re-bar.The electro-chemical corrosion results in to pitting corrosion-reduction in the cross section of the re-bar at specific sites without noticeable deterioration of the concrete cover. The hidden reduction in the cross-section of the reinforcement can results in to sudden failure of the structure member-making this as one of the most dangerous deterioration in the concrete structure. There is no ‘net use’ of chloride ions during the corrosion process. Therefore, once enough chloride ions reach the steel to break the passivation layer only water, oxygen and a conductive medium is needed to maintain the corrosion reaction. Also note that since corrosion is a chemical reaction, temperature plays a role in the process. The higher the temperature the faster the corrosion reaction occurs. The general rule for the rate of chemical reactions is that for every 25 degree F increases, the reaction rate doubles.Sulphate attack: The main source of sulphates is the ground water. The sulphates attack on concrete, by reacting with the C3A in the concrete. The reactive product is larger in the volume resulting in to the expansive cracking in the concrete mass. The spalling and cracking of concrete takes place without any deterioration of the reinforcement to start with. With the time other forms of corrosion such as carbonation, chlorides becomes aggravated due to quicker access to the reinforcement. The sulphate attack can be reduced by using sulphate resistant cement which has low C3A content; but this reduces the resistance of chloride attack and hence no more a preferred option in the marine situation.Alkali-silica reaction (ASR): In the case of ASR the alkali-reactive aggregates forms expansive gels in the concrete structure resulting in to cracking and spalling.Step-by-step process to successful repairs:-Following steps are essential for successful repairs:-??Evaluation??Relating observations to causes??Selecting methods and material for repairs??Preparation of drawings and specifications??Selection of contractor??Execution of the work??Quality control??Preserve records for futureEvaluationEvaluate the current condition of the concrete structure. Structural analysis of the structure in its deteriorated condition, review of records of any previous repair work accomplished, review of maintenance records, visual examination, destructive and noon-destructive testing and lab analysis of concrete samples. Some of the popular tests used during the evaluation are summarised as under:-??Visual inspection and recording??Hammer sounding / Rebound hammer test??Phenolphthalein test for carbonation??Silver-nitrate test for chloride attack??Half-cell potential measurement??Core-cutting??Chemical analysis of concrete at different depthsRepair philosophyIt is most important to consider the full load envelope, which has been acting on the structure during the complete service life and in the future. The repair materials must have compatibility with the existing structure. The compatibility may be defined as a balance (equilibrium) of physical, chemical, electrochemical and dimensional properties between the repair material and the existing substrate in structural exposure conditions for a determined period of time.1st Compatibility: Physical/Permeability??Allow substrate to breath??Prevent entry of water and waterborne salts – Sulphate, Chlorides, SO2, CO2 2nd Compatibility: Chemical??No negative chemical interaction with the substrate??Absence of potentially dangerous substances such as chlorides, alkalies??No expansive ettringite formation of sulphate3rd Compatibility: Electro-chemical??Higher resistance to corrosion current??Must have conductivity and should not isolate substrate??Effective passivation of re-bars4th Compatibility: Dimensional stabilityCoefficient of Thermal Expansion: Different Coefficients of Thermal Expansion causes differential movement and hence shall be avoided.Modules of Elasticity: Under compression materials of different module will cause stress at the interface and hence shall be avoided.Drying shrinkage: Drying shrinkage of fresh mortar causes stresses at interface; hence needs to be controlled to minimum.(Extract from the paper presented by the author at the Construction Chemicals International Conference 2012 held in Mumbai)(Extract from the paper presented by the author at the Construction Chemicals International Conference 2012 held in Mumbai)

Continue Reading
Click to comment

Leave a Reply

Your email address will not be published. Required fields are marked *

Concrete

Ramco Cements Campaign Wins Six Kyoorius Honours

Hard Worker campaign wins Grand Prix for Eco Plaster film

Published

on

By

Shares

The Ramco Cements Limited’s Hard Worker campaign has achieved a major milestone at the prestigious Kyoorius Creative Awards, winning six honours including the coveted Grey Elephant Grand Prix for the Eco Plaster film. The awards were announced and presented at the Kyoorius Creative Awards Night 2026 held on 23rd May 2026 at the Jio World Convention Centre, Mumbai.

Competing alongside some of the country’s leading brands and agencies, the campaign received recognition across multiple creative categories, reaffirming the power of authentic storytelling rooted in the lives of hardworking people. The Eco Plaster commercial, which highlighted the importance of water conservation through innovative construction solutions, emerged as the campaign’s biggest winner, securing most of the honours.

The campaign’s wins include: 
Grey Elephant (Grand Prix) – Eco Plaster 
Blue Elephant – Best Film – Eco Plaster
Blue Elephant – Best Direction – Eco Plaster
Blue Elephant – Best Music – Eco Plaster
Baby Elephant – Best Direction -Tortoise & Hare
Baby Elephant – Best Use of Humour – Eco Plaster

Established in 2014, the Kyoorius Creative Awards recognise and celebrate creative excellence across India’s advertising, marketing and communications industries. Presented by Zee Entertainment Enterprises and powered by the USA-based The Clio Awards, the awards are regarded among the country’s most respected creative honours.

Known for their ethical and neutral judging process, the Kyoorius Creative Awards evaluate work purely on merit through a non-hierarchical awards structure, without Gold, Silver or Bronze distinctions. The iconic Elephant symbolises memorable work that leaves a lasting impact on the industry.

The Hard Worker campaign by The Ramco Cements Limited was conceived around the insight that true strength and progress are built through everyday hard work. Through emotionally resonant storytelling, distinctive craft and culturally rooted narratives, the campaign connected strongly with audiences across markets. The integrated campaign was rolled out across television, digital platforms, outdoor media and extensive on-ground activations, helping strengthen the brand’s connect with consumers, engineers, masons and trade communities alike.

Commenting on the achievement, A V Dharmakrishnan, CEO of Ramco Cements, said: “Winning at the Kyoorius Creative Awards is a proud moment for all of us. The Hard Worker campaign was created as a tribute to the spirit of hardworking people who form the backbone of our industry and our nation. These recognitions reaffirm our belief that authentic, meaningful storytelling has the power to create a deep and lasting connection with people.”

Balaji K Moorthy, Executive Director – Marketing, Ramco Cements, added: “The Hard Worker campaign was built on a simple but powerful insight – that hard work deserves recognition and respect. We wanted the communication to feel rooted, emotional and culturally relevant while also pushing creative boundaries. Winning six honours, including the Grey Elephant Grand Prix, is a tremendous validation of the idea, the craft and the collaborative effort of everyone involved in the campaign.”

Continue Reading

Concrete

GP Petroleums Q4 PAT Rises 8%

Lubricant maker reports Rs 9.3 crore profit in Q4FY26

Published

on

By

Shares

GP Petroleums reported an 8 per cent rise in PAT to Rs 9.3 crore in Q4FY26, compared to Rs 8.6 crore in Q4FY25. Revenue from operations stood at Rs 163 crore, compared to Rs 183 crore in the corresponding quarter last year.

EBITDA for Q4FY26 increased to Rs 14.7 crore from Rs 13.2 crore in Q4FY25, while EBITDA margin improved to 9 per cent from 7 per cent. The company said its performance was supported by operational efficiencies, strong customer relationships and an expanding product portfolio.

For FY26, revenue from operations rose 5 per cent to Rs 643 crore, compared to Rs 610 crore in FY25. EBITDA stood at Rs 44.7 crore, against Rs 42 crore in the previous year. PAT was Rs 26.50 crore, marginally higher than Rs 26.30 crore in FY25.

The company said FY26 PAT was impacted by a wage provision of Rs 3.25 crore, representing about 12 per cent of PAT. GP Petroleums continues to see opportunities in industrial lubricants, process oils and premium automotive lubricants, though geopolitical developments and crude-linked raw material cost volatility may pose short-to-medium-term challenges.

Continue Reading

Concrete

Ramky Infra Order Book Crosses Rs 13,000 Crore

New order wins support resilient FY2026 performance

Published

on

By

Shares

Ramky Infrastructure reported a resilient FY2026 performance, supported by disciplined execution, cost efficiency and fresh order wins. The company secured new orders worth Rs 4,500 crore during Q4, taking its total order book above Rs 13,000 crore as of 31 March 2026.

Consolidated PAT grew 40 per cent year-on-year to Rs 283 crore in FY2026, compared to Rs 202 crore in FY2025. Standalone PAT rose 28 per cent to Rs 332 crore, while consolidated revenue from operations stood at Rs 1,846 crore. Standalone revenue from operations was Rs 1,679 crore.

During the year, the company secured orders worth Rs 6,500 crore across water, wastewater and industrial infrastructure. Key wins included a Rs 3,000 crore industrial park project from Maharashtra Industrial Development Corporation for a 1,000-hectare land parcel at Dighi Port Industrial Area, Maharashtra.

Ramky also secured a Rs 2,100 crore water and wastewater project from Hyderabad Metropolitan Water Supply and Sewerage Board for water transmission lines, and a Rs 1,400 crore EPC contract from Maharashtra Industrial Township Limited for the Dighi Port Industrial Area project.

The company generated Rs 160 crore through asset monetisation and Rs 165 crore through the stake sale of a stabilised asset, supporting equity requirements for new projects. The Board also recommended a final dividend of 10 per cent of the nominal value per share, subject to members’ approval.

Continue Reading

Video Thumbnail

    SIGN-UP FOR OUR GENERAL NEWSLETTER


    Trending News

    SUBSCRIBE TO THE NEWSLETTER

     

    Don't miss out on valuable insights and opportunities to connect with like minded professionals.

     


      This will close in 0 seconds